PPVIECEX 2 & 4 Output Flipper Valves

The PPVIECEX2OUT and PPVIECEX4OUT are ATEX and IECEx certified DIN rail mounted units housing 2 or 4 normally closed (NC) flipper valves for pneumatic control in Zone 2 gas hazardous areas. Directly compatible with Dini Argeo DFWIECEX digital outputs, both models carry intrinsic safety (Ex ia) certification to II 2G Ex ia IIC T6…T4 Gb, covering the IIC gas group at EPL Gb.

Model

£510.00
Product Information

PPVIECEX2OUT & PPVIECEX4OUT — ATEX & IECEx DIN Rail Flipper Valve Units for Zone 2 Gas Hazardous Areas

The PPVIECEX2OUT and PPVIECEX4OUT are DIN rail mounted intrinsically safe valve units, each housing normally closed (NC) flipper valves for pneumatic control in ATEX Zone 2 gas hazardous environments. Directly compatible with the digital outputs of Dini Argeo DFWIECEX ATEX weighing indicators, they provide a clean, compact solution for setpoint-driven pneumatic switching without additional safety interfaces. Both models carry ATEX and IECEx certification to II 2G Ex ia IIC T6…T4 Gb.

Key Features

  • DIN rail mount — compact, panel-friendly installation in safe area or Zone 2 control cabinets.
  • Normally closed (NC) flipper valves — safe-state closed for reliable process control.
  • Directly compatible with DFWIECEX digital outputs — no additional safety barriers required.
  • Available in 2-output (PPVIECEX2OUT) and 4-output (PPVIECEX4OUT) configurations.
  • Dual certified: ATEX and IECEx — suitable for international hazardous area installations.
  • Gas protection: II 2G Ex ia IIC T6…T4 Gb (Zone 2, EPL Gb, IIC gas group).
  • Intrinsic safety (Ex ia) protection mode.
  • Conforms to the ATEX Directive and IECEx certification scheme.

Available Models

  • PPVIECEX2OUT — DIN rail unit with 2 × normally closed (NC) flipper valves.
  • PPVIECEX4OUT — DIN rail unit with 4 × normally closed (NC) flipper valves.

ATEX & IECEx Certification

  • Full marking: II 2G Ex ia IIC T6…T4 Gb
  • Protection method: Intrinsic safety Ex ia
  • Gas group: IIC (hydrogen-rated — most stringent gas classification)
  • Equipment category: 2G (Zone 2 gas)
  • Temperature class: T6 to T4
  • EPL: Gb (Zone 2 equipment protection level for gas)
  • Conforms to the ATEX Directive and IECEx certification scheme
Specification

Valve Type & Operation

  • Type: Flipper valve, normally closed (NC)
  • Mounting: DIN rail
  • Default state: Normally closed (NC)
  • Compatibility: Dini Argeo DFWIECEX digital outputs

Available Models

  • PPVIECEX2OUT: 2 × NC flipper valves
  • PPVIECEX4OUT: 4 × NC flipper valves

ATEX & IECEx Certification — Gas

  • Full marking: II 2G Ex ia IIC T6…T4 Gb
  • Protection method: Intrinsic safety Ex ia
  • Gas group: IIC (hydrogen-rated)
  • Equipment category: 2G (Zone 2 gas)
  • Temperature class: T6 to T4
  • EPL: Gb (Zone 2 equipment protection level for gas)

Standards & Compliance

  • ATEX Directive compliant
  • IECEx certified