IECEXPW & IECEXPW24 — IECEx & ATEX Certified Power Supply for DFWIECEX
The IECEXPW range provides IECEx and ATEX certified power supplies specifically designed for use with the Dini Argeo DFWIECEX intrinsically safe weighing indicator. Certified to protection class S6 and rated for both Zone 2 gas and Zone 22 dust hazardous environments, each unit is supplied complete with a 6 m input cable for mains connection and a 3 m output cable for connection to the DFWIECEX indicator — ready for immediate installation. Available in two input voltage variants to suit your site supply.
Key Features
- Specifically designed for the Dini Argeo DFWIECEX ATEX weighing indicator.
- Dual certified: ATEX and IECEx — suitable for international hazardous area installations.
- Protection class S6.
- Gas protection: II 2(2)G Ex q [ib Gb] IIC T4 Gb X (Zone 2 gas).
- Dust protection: II 2(2)D Ex tb [ib Db] IIIC T135 °C Db X (Zone 22 dust).
- Operating temperature: Ta = 0 °C to +50 °C.
- Supplied with 6 m input cable and 3 m output cable as standard.
- Includes printed safety instructions and EU Declaration of Conformity ATEX (EN, DE, FR, ES, IT).
- Please refer to the instruction manual for full installation and safety information.
Available Models
- IECEXPW — 110–230 Vac input. For standard single-phase mains supply.
- IECEXPW24 — 24 V input (AC or DC). For 24 V site supplies.
ATEX & IECEx Certification
Gas:
- Marking: II 2(2)G Ex q [ib Gb] IIC T4 Gb X
- Protection methods: Powder filling (Ex q) with intrinsic safety [ib Gb]
- Gas group: IIC (hydrogen-rated)
- Equipment category: 2(2)G (Zone 2 gas)
- Temperature class: T4
- EPL: Gb
Dust:
- Marking: II 2(2)D Ex tb [ib Db] IIIC T135 °C Db X
- Protection methods: Enclosure protection (Ex tb) with intrinsic safety [ib Db]
- Dust group: IIIC (conductive dust)
- Equipment category: 2(2)D (Zone 22 dust)
- Surface temperature: T135 °C
- EPL: Db